22 lines
735 B
Markdown
22 lines
735 B
Markdown
|
### Setting Up a Node with Multiple NICs
|
||
|
|
||
|
* First, configure hardware interfaces in the VPP startup config, as
|
||
|
described [here](https://github.com/contiv/vpp/blob/master/docs/VPP_CONFIG.md#multi-nic-configuration).
|
||
|
|
||
|
* For each interface owned by Linux, you need to provide individual
|
||
|
configuration for each interface used by VPP in the Node Configuration
|
||
|
for thenode in the `contiv-vpp.yaml`. For example, if both `ens3` and
|
||
|
`ens4` are known to Linux, then put the following stanza into the node's
|
||
|
NodeConfig:
|
||
|
```
|
||
|
...
|
||
|
NodeConfig:
|
||
|
- NodeName: "ubuntu-1"
|
||
|
StealInterface: "ens3"
|
||
|
StealInterface: "ens4"
|
||
|
...
|
||
|
```
|
||
|
If only `ens3` is known to Linux, you only put a line for `ens3` into the
|
||
|
above NodeConfig.
|
||
|
|