Change-Id: I9fca8fb98502dffc2555f9de7f507b6f006e0e77 Signed-off-by: John DeNisco <jdenisco@cisco.com>
118 lines
4.3 KiB
ReStructuredText
118 lines
4.3 KiB
ReStructuredText
.. _subinterfacecommands:
|
|
|
|
.. toctree::
|
|
|
|
Create Sub-Interfaces
|
|
=====================
|
|
This command is used to add VLAN IDs to interfaces, also known as
|
|
subinterfaces. The primary input to this command is the '*interface*'
|
|
and '*subId*' (subinterface Id) parameters. If no additional VLAN ID is
|
|
provide, the VLAN ID is assumed to be the '*subId*'. The VLAN ID and
|
|
'*subId*' can be different, but this is not recommended.
|
|
|
|
This command has several variations:
|
|
|
|
- **create sub-interfaces <interface> <subId>** - Create a subinterface
|
|
to process packets with a given 802.1q VLAN ID (same value as the
|
|
'*subId*').
|
|
- **create sub-interfaces <interface> <subId> default** - Adding the
|
|
'*default*' parameter indicates that packets with VLAN IDs that do
|
|
not match any other subinterfaces should be sent to this
|
|
subinterface.
|
|
- **create sub-interfaces <interface> <subId> untagged** - Adding the
|
|
'*untagged*' parameter indicates that packets no VLAN IDs should be
|
|
sent to this subinterface.
|
|
- **create sub-interfaces <interface> <subId>-<subId>** - Create a
|
|
range of subinterfaces to handle a range of VLAN IDs.
|
|
- **create sub-interfaces <interface> <subId> dot1q|dot1ad <vlanId>|any
|
|
[exact-match]** - Use this command to specify the outer VLAN ID, to
|
|
either be explicited or to make the VLAN ID different from the
|
|
'*subId*'.
|
|
- **create sub-interfaces <interface> <subId> dot1q|dot1ad <vlanId>|any
|
|
inner-dot1q <vlanId>|any [exact-match]** - Use this command to
|
|
specify the outer VLAN ID and the innner VLAN ID.
|
|
|
|
When '*dot1q*' or '*dot1ad*' is explictly entered, subinterfaces can be
|
|
configured as either exact-match or non-exact match. Non-exact match is
|
|
the CLI default. If '*exact-match*' is specified, packets must have the
|
|
same number of VLAN tags as the configuration. For non-exact-match,
|
|
packets must at least that number of tags. L3 (routed) interfaces must
|
|
be configured as exact-match. L2 interfaces are typically configured as
|
|
non-exact-match. If '*dot1q*' or '*dot1ad*' is NOT entered, then the
|
|
default behavior is exact-match.
|
|
|
|
Use the '*show interface*' command to display all subinterfaces.
|
|
|
|
Summary/Usage
|
|
-------------
|
|
|
|
.. code-block:: shell
|
|
|
|
create sub-interfaces <interface> {<subId> [default|untagged]} | {<subId>-<subId>} | {<subId> dot1q|dot1ad <vlanId>|any [inner-dot1q <vlanId>|any] [exact-match]}.
|
|
|
|
Examples
|
|
--------
|
|
|
|
Example of how to create a VLAN subinterface 11 to process packets on 802.1q VLAN ID 11:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 11
|
|
|
|
The previous example is shorthand and is equivalent to:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 11 dot1q 11 exact-match
|
|
|
|
Example of how to create a subinterface number that is different from the VLAN ID:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 11 dot1q 100
|
|
|
|
Examples of how to create q-in-q and q-in-any subinterfaces:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 11 dot1q 100 inner-dot1q 200
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 12 dot1q 100 inner-dot1q any
|
|
|
|
Examples of how to create dot1ad interfaces:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 11 dot1ad 11
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 12 dot1ad 100 inner-dot1q 200
|
|
|
|
Examples of '*exact-match*' versus non-exact match. A packet with outer VLAN 100 and inner VLAN 200 would match this interface, because the default is non-exact match:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 5 dot1q 100
|
|
|
|
However, the same packet would NOT match this interface because '*exact-match*' is specified and only one VLAN is configured, but packet contains two VLANs:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 5 dot1q 100 exact-match
|
|
|
|
Example of how to created a subinterface to process untagged packets:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 5 untagged
|
|
|
|
Example of how to created a subinterface to process any packet with a VLAN ID that does not match any other subinterface:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# create sub-interfaces GigabitEthernet2/0/0 7 default
|
|
|
|
When subinterfaces are created, they are in the down state. Example of how to enable a newly created subinterface:
|
|
|
|
.. code-block:: console
|
|
|
|
vpp# set interface GigabitEthernet2/0/0.7 up
|
|
|